Cited sources
Follow each reference back to the article that uses it. The publications and manuals linked here remain on their publishers’ websites.
A better Z′ can hide a worse measurement
1. Zhang JH, Chung TDY, Oldenburg KR. A simple statistical parameter for use in evaluation and validation of high throughput screening assays. Journal of Biomolecular Screening. 1999;4(2):67–73. DOI: 10.1177/108705719900400206. Formula also presented in reference 4, section 2.
2. Hamamatsu Photonics. Photon Counting SNR Simulator. Count Rate Linearity section and paralyzable response equation. Accessed September 24, 2026.
3. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition. Printed pp. 145–147 on pulse-height discrimination, pp. 149–150 on count-rate linearity/correction, and p. 181 on over-light detection and attenuation checks; PDF pp. 158–160, 162–163 and 194.
4. Bray MA, Carpenter A. Advanced Assay Development Guidelines for Image-Based High Content Screening and Analysis. Assay Guidance Manual. July 8, 2017. Section 2, Z′ and V-factor discussions.
5. Promega. CellTiter-Glo 2.0 Assay technical manual TM403. Revised January 2023. Section 4.B, Cellular ATP Content; PDF p. 11 / printed p. 10.
6. Assay Development for Protein Kinase Enzymes. Assay Guidance Manual. Pilot Screens section. Accessed September 24, 2026.
When reading longer stops helping
1. Hamamatsu Photonics. Photon Counting SNR Simulator. Photon statistics and signal/background contributions; accessed September 24, 2026.
2. Owicki JC. Fluorescence Polarization and Anisotropy in High Throughput Screening: Perspectives and Primer. Journal of Biomolecular Screening. 2000;5:297–306.
3. Chang TC and colleagues. Microwell arrays reveal cellular heterogeneity during the clonal expansion of transformed human cells. Technology. 2015;3:163–171. Initial seeding statistics and subsequent clonal behavior in their microwell system.
4. Promega. CellTiter-Glo 2.0 Cell Viability Assay Technical Manual TM403. Revision 1/23, section 4; temperature and ATP-per-cell considerations. Worked examples in this article are constructed calculations, not measurements from this manual.
DNA quantification: five methods, five different answers
D1 Thermo Fisher — NanoDrop family brochure, BR51530
D2 Thermo Fisher — Qubit assays and assay ranges
D3 Thermo Fisher — Qubit Flex user guide MAN0018186
D4 Thermo Fisher — UV versus fluorescence technical note
D5 DeNovix — DS-11 FX spectrophotometer/fluorometer
D6 Thermo Fisher — Quant-iT PicoGreen dsDNA reagent and kits, MP07581
D7 Promega — QuantiFluor ONE dsDNA System
D8 Roche — KAPA Library Quantification brochure
D9 Bio-Rad — QX600 Droplet Reader and QX Manager user guide
D10 QIAGEN — QIAcuity Digital PCR System
D11 Agilent — 4200 TapeStation System
D12 Agilent — 5300 Fragment Analyzer System
D13 Thermo Fisher — Qubit dsDNA HS frequently asked questions
D14 Bio-Rad — Introduction to Digital PCR
D15 Thermo Fisher — NanoDrop One frequently asked questions
D16 Thermo Fisher — Qubit NGS Library Quantification Assay Q34250
D17 Thermo Fisher — Qubit 1X dsDNA technical note
Microplate kinase assays: choose the event you need to measure
K1 Promega — ADP-Glo Kinase Assay technical manual TM313
K2 Promega — ADP-Glo Max Assay
K3 Promega — Kinase-Glo Platform technical bulletin TB372
K4 Thermo Fisher — Adapta Universal Kinase Assay user guide
K5 BellBrook Labs — Transcreener HTS assays
K6 BellBrook Labs — Transcreener frequently asked questions
K7 Revvity — HTRF KinEASE TK manual, revision 07 October 2025
K8 Revvity — LANCE Ultra kinase assays
K9 Thermo Fisher — Biochemical kinase assays
K10 Thermo Fisher — Z′-LYTE Tyr 5 user guide
K11 Revvity — Alpha kinase anti-phospho antibody assays
K12 Revvity — Alpha SureFire no-wash cellular kinase assays
K13 Revvity — DELFIA kinase assays
K14 Revvity — Radioactive in vitro kinase assays
K15 Thermo Fisher — LanthaScreen Eu Kinase Binding user guide
K16 Promega — NanoBRET target engagement technology
K17 Revvity — HTRF technical booklet
K18 Revvity — Alpha troubleshooting tables
K19 Promega — Kinase Enzyme Systems TM553
Automated confocal screening: compare the result, not the camera speed
C01 Revvity Opera Phenix OptIQ product and configuration matrix
C02 Revvity Opera Phenix OptIQ brochure, 2026
C03 Revvity Opera Phenix Plus technical performance: speed
C04 Revvity Operetta CLS product/configuration matrix
C05 Revvity Operetta CLS brochure, 2025
C06 Molecular Devices ImageXpress HCS.ai datasheet, January 2025
C07 Molecular Devices ImageXpress HCS.ai product page
C08 Molecular Devices ImageXpress Confocal HT.ai product page
C09 Yokogawa CellVoyager CV8000 product/specifications
C10 Yokogawa CV8000 brochure
C11 Yokogawa CQ3000 current product page
C12 Yokogawa CQ3000 brochure
C13 Thermo Scientific CellInsight CX7 LZR Pro current product page
C14 Thermo CellInsight CX7 LZR Pro specification sheet
C15 Thermo CellInsight CX7 LZR Pro user guide MAN0026043
C16 Molecular Devices: tips for successful live-cell imaging
C17 Versatile, do-it-yourself, low-cost spinning disk confocal microscope (primary research)
HTRF: the ratio is not the whole result
1. Revvity. HTRF Signal Treatment and Analysis. Per-well ratios, Delta F, negative controls and calibration.
2. Revvity. HTRF Technical Guide. HTRF detection and reader guidance; p. 20 discusses laser and flash-lamp excitation.
3. Revvity. HTRF Reader Control Kit, 62RCLPEA. Version 08, January 2026. Optical/software configuration and instrument-performance checks.
ADP-Glo: the light comes after the kinase
1. Promega. ADP-Glo Kinase Assay, TM313. Revised July 2023. Sections 3B, 4 and 5: conversion standards, reagent sequence, thermal guidance and interference controls.
2. Zegzouti H., Zdanovskaia M., Hsiao K. and Goueli S.A. ADP-Glo: A Bioluminescent and Homogeneous ADP Monitoring Assay for Kinases. Assay and Drug Development Technologies 7, 560–572 (2009). doi:10.1089/adt.2009.0222.
CellTiter-Glo: when less light doesn’t mean fewer cells
1. Chan GKY et al. A Simple High-Content Cell Cycle Assay Reveals Frequent Discrepancies between Cell Number and ATP and MTS Proliferation Assays. PLOS ONE 8(5), e63583 (2013). doi:10.1371/journal.pone.0063583.
2. Riss TL et al. Cell Viability Assays. Assay Guidance Manual. Updated July 1, 2016. Marker selection and the ATP assay principle.
3. Promega. CellTiter-Glo 2.0 Assay, TM403. Revised January 2023. Sections 3 and 4B: endpoint procedure, temperature, chemical interference, cell physiology and mixing.
HiBiT: did the protein disappear, or just the light?
1. Promega. Nano-Glo HiBiT Lytic Detection System, TM516. Revised June 2023. Sections 3, 6B, 6C, 6G and 6H: detection principle, temperature, tag accessibility, expression, background and reporter-interference controls.
2. Lin H. et al. Lysineless HiBiT and NanoLuc Tagging Systems as Alternative Tools for Monitoring Targeted Protein Degradation. ACS Medicinal Chemistry Letters 15, 1367–1375 (2024). doi:10.1021/acsmedchemlett.4c00271.
Your fluorescence polarization result is hiding two measurements
1. Hall MD and colleagues. Fluorescence polarization assays in high-throughput screening and drug discovery: a review. Methods and Applications in Fluorescence. 2016;4:022001. Equations, calibration, probe behavior, temperature and interference.
2. Owicki JC. Fluorescence Polarization and Anisotropy in High Throughput Screening: Perspectives and Primer. Journal of Biomolecular Screening. 2000;5:297–306. Photon-statistics discussion. Numerical channel examples here are constructed calculations.
3. Thermo Fisher Scientific. Fluorescence Polarization, Molecular Probes Handbook Note 1.4. Rotational motion, lifetime, viscosity and linker flexibility; accessed September 24, 2026.
Your fluorescent label is part of the experiment
1. Lakowicz JR (2006). Principles of Fluorescence Spectroscopy, third edition. Chapter 10, printed pp. 367–368: Perrin relation, rotational correlation time and local motion.
2. Inoyama D et al. (2012). Optimization of Fluorescently Labeled Nrf2 Peptide Probes and the Development of a Fluorescence Polarization Assay for the Discovery of Inhibitors of Keap1-Nrf2 Interaction. Journal of Biomolecular Screening 17:435–447. Table 4 and Figure 4; the latter notes that the cross-dye measurements were not G-adjusted. Nrf2 supplies the peptide; Keap1 is its binding partner.
3. Invitrogen. Predictor hERG Fluorescence Polarization Assay manual. Section 6.5, PDF p. 10: assay versus buffer blanks and the membrane-viscosity explanation for different low-control polarization values.
One extra carbon can change the binding result
2. Invitrogen. Fluorescence Polarization Technical Resource Guide, fourth edition. Chapter 8, PDF pp. 84–87: anisotropy, binding models and ligand depletion.
3. Lakowicz JR (2006). Principles of Fluorescence Spectroscopy, third edition. Chapter 10, printed pp. 367–368: rotational correlation, lifetime and local motion.
Half the molecules and two thirds of the light
1. Invitrogen. Fluorescence Polarization Technical Resource Guide, fourth edition. Anti-fluorescein example: PDF pp. 35–38, especially p. 37 (printed chapter 3, p. 15). Mixture equations, anisotropy conversion and binding analysis: PDF pp. 84–87.
2. Inoyama D et al. (2012). Optimization of Fluorescently Labeled Nrf2 Peptide Probes and the Development of a Fluorescence Polarization Assay for the Discovery of Inhibitors of Keap1-Nrf2 Interaction. Journal of Biomolecular Screening 17:435–447. Methods, equations 4–5, printed p. 438: brightness correction and ligand depletion. The study uses a bound/free brightness correction before fitting binding.
Why is my luminescence signal lower on one plate reader than another?
1. Messenger S. Promega. Just What Is an RLU (Relative Light Unit)?, 28 October 2020; checked 29 September 2026. Instrument-dependent reporting units. Web text reviewed; complete local archive unavailable.
2. Wieczorek D, Hooper K, Bjerke M. Promega. How Sensitivity and Crosstalk Affect Your Bioluminescent Assay Results, June 2019, tpub_212. Well isolation and plate opacity; no historical instrument ranking is carried forward.
3. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, archived revision January 2023, sections 3.B and 4.B, PDF pp. 7 and 11. Equilibration, stabilization and temperature-dependent light output.
What is the difference between analog and photon-counting luminescence detection?
1. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 144 and 149–151 (PDF pp. 157 and 162–164). Analog/counting readout, pulse resolution and dead-time models.
2. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021, p. 72. Analog-to-digital conversion and gain in the fluorescence path; this example does not identify every reader's luminescence architecture.
3. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, archived revision January 2023, PDF pp. 7 and 11. Equilibration and temperature effects on intensity and decay.
Can PMT saturation or signal compression occur without an overload warning?
1. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications. Fourth edition, April 2017. Section 6.3, printed pp. 149–150, PDF pp. 162–163; equations 6-2 through 6-4 and count-rate correction examples. Component/system examples are not commercial plate-reader specifications.
2. Zhang J-H, Chung TDY, Oldenburg KR. A Simple Statistical Parameter for Use in Evaluation and Validation of High Throughput Screening Assays. Journal of Biomolecular Screening. 1999;4(2):67–73. DOI: 10.1177/108705719900400206. Original Z-factor reference; PubMed abstract checked, full publisher article not retrieved for this draft.
Why do my bright controls have excellent CVs while my weak samples are unreliable?
1. National Institute of Standards and Technology (NIST). Coefficient of Variation. Definition, ratio-scale requirement and behavior near zero; checked 29 September 2026.
2. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 149–153 (PDF pp. 162–166). Counting linearity, background and signal-to-noise relationships.
3. BMG LABTECH. How does the number of flashes influence measurement results?. Flash averaging, concentration-dependent variability and acquisition time; checked 29 September 2026. Example-specific flash counts are not generalized.
Why does reading longer stop improving my assay CV?
1. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 152–153 (PDF pp. 165–166). Counting statistics and integration time. The variance example is a calculation under stated assumptions.
2. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, archived revision January 2023, sections 3.B and 4.B, PDF pp. 7 and 11. Protocol timing and temperature guidance.
Why do I get negative fluorescence or luminescence values after blank subtraction?
1. National Institute of Standards and Technology (NIST). Combining uncertainty components. Propagation of uncertainty, covariance and independent input quantities; checked 29 September 2026. Numerical examples here are derived illustrations.
2. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, archived revision January 2023, PDF pp. 7 and 11. Room-temperature equilibration, stabilization and temperature effects on intensity and decay.
3. National Institute of Standards and Technology (NIST). Coefficient of Variation. Definition, ratio-scale requirement and behavior near zero; checked 29 September 2026.
Why does subtracting background make my CV worse?
1. National Institute of Standards and Technology (NIST). Coefficient of Variation. Definition, ratio-scale requirement and behavior near zero; checked 29 September 2026.
2. National Institute of Standards and Technology (NIST). Combining uncertainty components. Propagation of uncertainty, covariance and independent input quantities; checked 29 September 2026. Numerical examples here are derived illustrations.
3. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 149–153 (PDF pp. 162–166). Counting linearity, background and signal-to-noise relationships.
Why are repeated readings of one well precise while replicate wells disagree?
1. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021, pp. 143–144. Separate tests of plate uniformity and repeated-read precision; historical instrument-specific procedures.
2. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual. Previously archived full chapter; plate geometry, handling, mixing and position effects.
3. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, archived revision January 2023, PDF pp. 7 and 11. Room-temperature equilibration, stabilization and temperature effects on intensity and decay.
How much does read height matter in fluorescence intensity?
1. BMG LABTECH. Fluorescence intensity, focal-height section. Sample location, fill volume and sensitivity. No universal percentage improvement is inferred.
2. Tecan. Maximize signal to blank intensity ratios, technical note 396815 V1.0, August 2011, pp. 1–4. Infinite M1000/F500 height optimization and optical settings. Historical, configuration-specific evidence.
Why can increasing PMT gain make low-signal fluorescence CV worse?
1. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications. Fourth edition, April 2017. Sections 4.3.7 and 6.3; printed pp. 75–79 and 152–153, PDF pp. 88–92 and 165–166. Detector-noise mechanisms; instrument-specific gain behavior still requires the reader manual.
2. Molecular Devices. PMT Gain Adjustment with Fluorescence and Luminescence Measurement. Application note. SpectraMax M5e examples and model-specific gain normalization, not a rule for every reader.
Should I use automatic gain on every plate in a screening run?
1. BMG LABTECH. How to optimise the gain setting of my microplate reader?. Gain selection, strongest-well adjustment and fixed-setting comparisons. Instrument-specific numerical settings and targeting percentages are not generalized.
2. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021, p. 72. Gain, supply voltage, converter range and fluorescence signal quality.
When does a wider fluorescence bandwidth improve sensitivity—and when does it make results worse?
1. BMG LABTECH. Wavelength and bandwidth optimisation on a microplate reader.
2. Tecan. Infinite 200 PRO Instructions for Use, no. 30125944, revision 1.4, June 2021, p. 32.
3. BMG LABTECH. Monochromator optical architecture.
4. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 152–153.
5. Tecan. Impact of Extended Adjustable Monochromator Bandwidth in Fluorescence Based Application Technologies, 396061 V1.0, August 2009, pp. 6–7.
Why do filter and monochromator readers perform differently at the same nominal wavelengths?
1. Tecan. Infinite 200 PRO Instructions for Use, no. 30125944, revision 1.4, June 2021, pp. 31–34. Grating selection, FWHM, double monochromators and optical geometry.
2. BMG LABTECH. Monochromator optical architecture. Manufacturer description of variable filter bands and dichroic separation.
3. Revvity. HTRF Technical Booklet, pp. 13 and 20. Ratiometric detection and reader-selection considerations.
What does a dichroic mirror change in a fluorescence measurement?
1. Semrock, IDEX Health & Science. Introduction to Fluorescence Filters. Excitation, dichroic and emission elements; transmission, blocking and passband selection.
2. BMG LABTECH. What is a dichroic mirror?. Manufacturer explanation of dichroics in plate-reader optical paths, including wavelength-selectable systems; comparative marketing rankings are not adopted here.
3. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 149–153 (PDF pp. 162–166). Counting noise, background and count-rate nonlinearity. Numerical examples here are constructed.
Should I always read at a fluorophore's published excitation and emission peaks?
1. Thermo Fisher Scientific. Fluorescein, Oregon Green and Rhodamine Green Dyes, Molecular Probes Handbook section 1.5. Table 1.4, FITC F143, and pH-dependence notes. Web passages only; full download unavailable.
2. Tecan. Impact of Extended Adjustable Monochromator Bandwidth in Fluorescence Based Application Technologies, technical note 396061, pp. 1–2 and assay examples. Historical instrument-specific demonstration of bandwidth, throughput and resolution tradeoffs.
3. Anton Simeonov and Mindy I. Davis. Interference with Fluorescence and Absorbance. Assay Guidance Manual, updated 1 July 2018. Reviewed in the supplied June 2026 compilation, PDF pp. 1259–1264, particularly p. 1262; current web access was blocked.
Top vs bottom read: which should I use for cell-based fluorescence?
1. BMG LABTECH. How to reduce autofluorescence in cell-based assays, HowTo Note 04, pp. 2–3. Adherent-cell top/bottom comparison and media effects; manufacturer experiment, not a universal performance ratio.
2. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual. Archived full chapter; plate color, bottom material, surfaces and optical crosstalk.
3. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021. Fluorescence top/bottom optics and measurement-parameter guidance; instrument-specific details require the relevant reader manual.
NanoBRET: proximity needs a good alibi
1. Promega. NanoBRET Protein:Protein Interaction System, TM439. Revised October 2023. Sections 4B, 5C, 6, 7 and 10B cover detection, kinetic equilibration, ratio correction and assay controls.
2. Lan TH et al. BRET evidence that β2 adrenergic receptors do not oligomerize in cells. Scientific Reports 5, 10166 (2015). doi:10.1038/srep10166.
3. White CW et al. Using nanoBRET and CRISPR/Cas9 to monitor proximity to a genome-edited protein in real-time. Scientific Reports 7, 3187 (2017). doi:10.1038/s41598-017-03486-2.
4. Promega. Nano-Glo Endurazine and Vivazine Live Cell Substrates, TM550. Revised October 2025. Sections 3D–3F discuss measurement conditions, thermal gradients, evaporation and background.
TR-FRET: waiting doesn’t fix the wrong photons
1. Revvity. HTRF Technical Booklet, especially pp. 9, 13 and 17. Donor-fed delayed acceptor emission, detection principles and temperature qualifications.
2. Thermo Fisher Scientific. LanthaScreen assay FAQs, emission-filter and assay-window questions.
3. Thermo Fisher Scientific. Method to Test Microplate Readers for LanthaScreen Tb Assays. September 20, 2010, pp. 1–3. Historical manufacturer procedure; check current assay-specific instructions before use.
4. Life Technologies/Thermo Fisher Scientific. LanthaScreen Terbium Assay Setup Guide on the EnVision Multilabel Reader. April 13, 2012, especially p. 2. Configuration-specific lamp/laser and optical guidance; not a current comparative performance study.
5. Revvity. HTRF Reader Control Kit. Version 08, January 2026. Optical/software validation, incubation schedules and stability windows. Numerical examples in this article are constructed calculations, not measured reader performance.
Why does an HTRF assay have good signal-to-background but poor Z-prime?
1. Zhang J-H, Chung TDY, Oldenburg KR. A Simple Statistical Parameter for Use in Evaluation and Validation of High Throughput Screening Assays. Journal of Biomolecular Screening. 1999;4(2):67–73. DOI: 10.1177/108705719900400206. Original Z-factor paper; PubMed abstract accessed, full publisher text not retrieved for this draft. Formula also corroborated in the project’s NIH Assay Guidance Manual.
2. Revvity. HTRF Signal Treatment and Analysis and HTRF Technical Booklet, pp. 13–17 and 20. Per-well ratios, signal treatment, temperature and reader principles; web
3. Revvity. HTRF Reader Control Kit 62RCLPEA. Version 08, January 2026; PDF pp. 2–4. Reader qualification controls and timing conditions.
How should I optimize NanoBRET donor and acceptor filters?
1. Promega. NanoBRET Protein:Protein Interaction System Technical Manual TM439, revision October 2023, sections 1, 3.A and 6. Donor/acceptor identity, filters and ratio correction. Settings are specific to the stated assay format.
2. BMG LABTECH. Simultaneous dual emission. Paired channel collection and matched PMTs. Timing benefits require assay-specific verification.
Why does my HTRF assay still have high background after I increase the delay time?
1. Revvity. HTRF Technical Booklet. Pages 9–13 and 20. Donor-fed delayed acceptor emission, red acceptors, time-resolved detection and excitation-source guidance.
2. Revvity. HTRF Signal Treatment and Analysis. Ratio definition, background corrections and assay-format-specific negative controls.
3. Revvity. HTRF Reader Control Kit 62RCLPEA. Version 08, January 2026; PDF pp. 2–4. Defined blank, donor, acceptor and calibrator controls for reader qualification.
4. Goodrich W, Amouretti X, Banks P, Degorce F, Pierre N. HTRF Ligand Binding Assay for the Chemokine Receptor CXCR4. Agilent/Cisbio application note 5994-3104EN; PDF p. 3. Configuration-specific optical bands and read timing.
When does laser excitation improve an HTRF or TR-FRET assay?
1. Revvity. HTRF Technical Booklet, pp. 9–13 and 20. Donors, acceptors, delayed detection and excitation-source guidance.
2. BMG LABTECH. TRF laser. Manufacturer description of a 337 nm pulsed nitrogen laser and 60 s⁻¹ pulse rate. No universal performance advantage is inferred from these specifications.
3. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 152–153 (PDF pp. 165–166). Photon-counting signal-to-noise principles.
What does a dedicated TR-FRET detector add beyond time-gating a general-purpose PMT?
1. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, sections 4.3.2, 4.3.6–4.3.9 and 5.1.7. Gain, linearity, noise, afterpulsing, polarization dependence and detector gating.
2. BMG LABTECH. PHERAstar detection system. Manufacturer description of two matched detector pairs, including a pair optimized for time-resolved fluorescence. Complete page archived 29 September 2026; architecture is not independent performance validation.
3. Revvity. HTRF Technical Booklet, pp. 9–13 and 20. Lanthanide donors, emission channels, delayed detection and excitation-source guidance. Archived complete PDF.
Why can a white plate outperform a black plate in a TR-FRET assay?
1. Revvity. HTRF Technical Booklet, pp. 9–13 and 19–20. Delayed detection, red donor/acceptor channels, plate recommendations and excitation sources.
2. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 149–153 (PDF pp. 162–166). Counting noise, background and count-rate nonlinearity. Numerical examples here are constructed.
3. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual. Archived full chapter; plate color, bottom material, surfaces and optical crosstalk.
Choosing assays for molecular glue and PROTAC screening
A3 Revvity HTRF PPI assay development guide
A8 Promega NanoBRET Protein Protein Interaction System TM439
P1 Promega TarSeer BRETSA Target Engagement technology and early access
P2 BRETTSA primary conference abstract 6427 Cancer Research 2026
P3 Jafari et al 2014 CETSA protocol abstract and figures
P4 Robers et al 2015 Cellular engagement and residence time with BRET
P5 Promega NanoBRET CRBN and VHL Ternary Complex Assays TM615 revised January 2024
P6 Promega Nano-Glo HiBiT Lytic Detection TM516 revised June 2023
P7 Smith et al 2019 Differential PROTAC substrate specificity dictated by recruited ligase orientation
P8 Slabicki et al 2020 CR8 molecular glue depletes cyclin K
P9 Mayor-Ruiz et al 2020 Molecular glue discovery by chemical profiling
P10 Roy et al 2019 SPR ternary complex kinetics and PROTAC degradation
P11 Promega target degradation assay selection
The ratio survived but the precision did not
1. Hall MD et al. Fluorescence polarization assays in high-throughput screening and drug discovery: a review. Methods and Applications in Fluorescence 4 (2016), 022001. Supplied PDF pp. 26–27: proportional versus additive interference and follow-up; p. 23: temperature.
2. Owicki JC (2000). Fluorescence polarization and anisotropy in high throughput screening: perspectives and primer. Journal of Biomolecular Screening 5:297–306. Supplied Fluorescence Methods in Drug Discovery collection, PDF p. 131: shot-noise treatment. Numerical examples here are independently calculated idealized cases.
More receptor can make affinity harder to measure
1. Invitrogen. Fluorescence Polarization Technical Resource Guide, fourth edition. Ligand depletion and quadratic binding: PDF pp. 68–69. Optical weighting and binding analysis: PDF pp. 84–87.
2. Jarmoskaite I, AlSadhan I, Vaidyanathan PP, Herschlag D (2020). How to measure and evaluate binding affinities. eLife 9:e57264. Sections “Avoid the titration regime,” “Vary incubation time to test for equilibration” and “Determine the fraction of active protein.” DOI: 10.7554/eLife.57264.
When does simultaneous dual-emission detection improve FP, TR-FRET or BRET precision?
1. BMG LABTECH. Simultaneous dual emission. Paired PMTs and simultaneous spectral or polarization channels. Manufacturer performance claims are not treated as universal guarantees.
2. Revvity. HTRF Technical Booklet, pp. 9–13. Delayed detection, donor/acceptor channels and ratiometric measurement.
3. Molecular Devices. Establishing and optimizing a fluorescence polarization assay. Background subtraction and G-factor calibration. No instrument-specific polarization target is prescribed here.
Are two PMTs enough for accurate ratiometric measurements, or do they need matching and calibration?
1. BMG LABTECH. PHERAstar detection system. Manufacturer description of two matched detector pairs, including a pair optimized for time-resolved fluorescence. Complete page archived 29 September 2026; architecture is not independent performance validation.
2. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021, pp. 79–84. Channel blank subtraction, G-factor calibration, filter-specific records and polarization calculation.
3. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, sections 4.3.2, 4.3.6–4.3.9 and 5.1.7. Gain, linearity, noise, afterpulsing, polarization dependence and detector gating.
Why can my NanoBRET ratio stay constant while the donor signal falls?
1. Promega. NanoBRET Protein:Protein Interaction System Technical Manual TM439, revision October 2023. Sections 3.A, 5.D and 6; Figure 8, printed p. 20 (PDF p. 21). Filters, live-cell conditions, corrected ratios and the low-donor example.
2. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 152–153 (PDF pp. 165–166). Photon-counting noise principles. The ratio calculation is an explicitly derived example, not a manufacturer performance claim.
Why does the mP value of my free FP tracer change when I change its concentration?
1. Hall MD and colleagues. Fluorescence polarization assays in high-throughput screening and drug discovery: a review. Methods and Applications in Fluorescence 2016;4:022001. Supplied full PDF, sections 2, 4 and 5: polarization calculation, assay development, concentration dependence and interference.
2. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021, pp. 79–84. Channel blank subtraction, G-factor calibration, filter-specific records and polarization calculation.
3. Thermo Fisher Scientific. PolarScreen Nuclear Receptor Competitor Assays Universal Protocol, MAN0007703 revision A.0, 12 March 2014, pp. 2–3 and 8. Green/red filter settings, FP reference kit, assay controls and room-temperature incubation; check the target-specific product sheet.
Can I reuse the same FP G factor after changing filters, gain settings or readers?
1. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021, pp. 79–84. Channel blank subtraction, G-factor calibration, filter-specific records and polarization calculation.
2. Thermo Fisher Scientific. PolarScreen Nuclear Receptor Competitor Assays Universal Protocol, MAN0007703 revision A.0, 12 March 2014, pp. 2–3 and 8. Green/red filter settings, FP reference kit, assay controls and room-temperature incubation; check the target-specific product sheet.
3. BMG LABTECH. PHERAstar detection system. Manufacturer description of two matched detector pairs, including a pair optimized for time-resolved fluorescence. Complete page archived 29 September 2026; architecture is not independent performance validation.
Choosing a microplate: the plastic is part of the assay
1. Auld DS and colleagues. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual, June 1, 2020. Supplied project compilation, PDF pp. 1309–1344; surfaces, geometry, handling, lots and positional effects.
2. Corning. Nonbinding surface treatment. Mechanism and intended applications. No universal adsorption capacity is assumed in the worked example.
3. Corning. Microplates Product Selection Guide, especially the color and well-geometry guidance; an earlier selection guide is also retained in the project library.
4. Revvity. A Guide to Developing Biochemical Assays with HTRF PPi Reagents, pp. 30–31. Plate types, working volumes and white/black comparisons within the guide's scope.
5. Promega. CellTiter-Glo 2.0 Cell Viability Assay Technical Manual TM403. Revision 1/23, printed p. 10. Plate construction, crosstalk and temperature equilibration.
6. Revvity. Microplates for Luminescence Assays. Phosphorescence and plate-dependent signal/crosstalk comparisons. Numerical examples in this article are constructed calculations, not measurements from this source.
Controls can look better when the detector stops telling the truth
1. Bray MA, Carpenter A. Advanced Assay Development Guidelines for Image-Based High Content Screening and Analysis. Assay Guidance Manual, chapter dated July 8, 2017; supplied compilation updated June 10, 2026. PDF pp. 771–773, especially p. 773 / printed p. 751: saturation artifacts and response-curve metrics. This is a general statistical warning, not a documented photon-counting screen failure.
2. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition. PDF pp. 158–163 / printed pp. 145–150: pulse discrimination and count-rate linearity; PDF p. 194 / printed p. 181: attenuation checks.
3. Promega. CellTiter-Glo 2.0 Assay technical manual TM403. Revised January 2023; PDF p. 11 / printed p. 10, temperature and equilibration guidance. Instructions are specific to this kit.
What causes crosstalk in 384- and 1536-well plates?
1. Wieczorek D, Hooper K, Bjerke M. Promega. How Sensitivity and Crosstalk Affect Your Bioluminescent Assay Results, June 2019, tpub_212. Well isolation, opacity and bright-neighbor testing; historical product rankings are not generalized.
2. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, archived revision January 2023, PDF pp. 7 and 11. Temperature, stabilization and clear-bottom plate caveats.
Why can crosstalk correction fix the mean but leave weak wells unreliable?
1. Wieczorek D, Hooper K, Bjerke M. Promega. How Sensitivity and Crosstalk Affect Your Bioluminescent Assay Results, June 2019, tpub_212. Well isolation, plate opacity and the Kinase-Glo Max challenge design.
2. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 152–153 (PDF pp. 165–166). Counting noise with background. The exact-background subtraction examples are derived calculations.
3. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, archived revision January 2023, sections 3.B and 4.B, PDF pp. 7 and 11. Temperature, plate equilibration and clear-bottom plate caveats.
What causes a plate edge effect: evaporation, temperature or cell biology?
1. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual. Archived full chapter, sections on incubation, evaporation, positional effects and well effects.
2. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, revised January 2023, PDF pp. 7 and 11. Room-temperature protocol, signal temperature dependence and stack equilibration.
3. Lundholt BK, Scudder KM, Pagliaro L. A Simple Technique for Reducing Edge Effect in Cell-Based Assays. Journal of Biomolecular Screening 2003;8(5):566–570. Publisher abstract reviewed; full paper unavailable. No universal pre-incubation duration is inferred.
Why does my assay have low Z-prime after moving from 384 to 1536 wells?
1. Bray MA, Carpenter A. Advanced Assay Development Guidelines for Image-Based High Content Screening and Analysis. Assay Guidance Manual, 2017 update. Statistical assessment of controls and assay quality.
2. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual. Plate geometry, dispensing, mixing and evaporation; previously archived full chapter reviewed.
3. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, archived revision January 2023, sections 3.B and 4.B, PDF pp. 7 and 11. Equilibration, temperature and plate-selection caveats.
4. Revvity. HTRF Technical Booklet, pp. 13 and 20. Ratiometric detection and excitation-source guidance. Timing-error reduction is a mechanism-based inference, not a quantified advantage for every assay.
Why does absorbance change when I change the volume, even at the same concentration?
1. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021, pp. 42–43, 92–99 and 159. Pathlength correction, injector operation and application-dependent cleaning.
2. Molecular Devices. Optical density measurements automatically corrected to a 1-cm pathlength with PathCheck Technology. Water absorption, temperature and background correction.
Can a plate lid or sealing film change my fluorescence, luminescence or absorbance results?
1. Eppendorf. PCR films and foils. Masterclear real-time PCR Film transmission specification and closure compatibility.
2. BMG LABTECH. How to optimise OD600 measurements, HowTo Note 10, p. 5. Condensation-related optical-density artifacts; complete six-page note archived.
3. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021, pp. 42–43, 92–99, 132 and 159. Pathlength correction, injector operation and application-dependent cleaning.
4. Tecan. Selecting the right plate for a measurement. Manufacturer guidance on covers in absorbance, top/bottom fluorescence and luminescence.
The plate is recording its temperature history
1. PerkinElmer. AlphaScreen practical guide. PDF pp. 30 and 32, printed pp. 24 and 26: separate time-point wells, temperature sensitivity and equilibration. Historical examples remain assay-specific.
2. Promega. CellTiter-Glo 2.0 Assay technical manual TM403. Revised January 2023, PDF p. 11, section 4.B. Temperature and plate-construction guidance.
3. Promega. ADP-Glo Kinase Assay technical manual TM313. Revised July 2023, PDF pp. 17–18. Temperature and plate-construction guidance.
4. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual, supplied 2021 compilation, PDF pp. 1337 and 1341–1342: incubation, evaporation and spatial effects. Qualification experiments here are proposed. The photon-counting example is a constructed statistical calculation, not measured reader performance.
The plate queue changed your IC50
1. Promega. ADP-Glo Kinase Assay technical manual TM313. Revised July 2023. Sections 4.B–4.E and 5, especially PDF pp. 17–18: reaction staging and temperature guidance.
2. PerkinElmer. AlphaScreen practical guide. PDF p. 30, printed p. 24: time courses, multiple plates and the cAMP example.
3. Promega. CellTiter-Glo 2.0 Assay technical manual TM403. Revised January 2023. PDF p. 11, section 4.B: temperature, decay and stack equilibration.
4. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual, supplied 2021 compilation, PDF pp. 1337 and 1342: positional effects and timing.
5. Revvity. AlphaPlex assay development user guide. PDF pp. 12–13: sequential versus simultaneous detection. The guide also reports comparable sensitivity for the configurations it discusses; no numerical throughput improvement is assumed here.
Your Alpha assay is also a thermometer
1. PerkinElmer. AlphaScreen practical guide. Especially PDF pp. 7, 30, 32 and 37; printed pp. 1, 24, 26 and 31. Legacy guide supplied to this project; public copy linked for readers.
2. Revvity. AlphaLISA and AlphaScreen no-wash assays. Temperature FAQ.
3. Revvity. Alpha troubleshooting tables. Signal inconsistency and temperature guidance.
4. Assay Guidance Manual, supplied 2021 compilation. Microplate incubation and plate-effects discussion, PDF pp. 1337–1344, especially p. 1342 / printed p. 1322. Online chapter entry; the cited text was checked in the supplied 2021 edition.
5. Promega. CellTiter-Glo 2.0 Assay technical manual TM403. Revised January 2023. Section 4.B, PDF p. 11 / printed p. 10.
6. Revvity. AlphaPlex assay development user guide. Incubation guidance and optics selection, pp. 8 and 12–13.
Why does my plate reader warm the plate when incubation is switched off?
1. BMG LABTECH. Advanced Assay Stability. Manufacturer engineering description. Discusses internal heat and heating/cooling of the measurement chamber. Numerical competitive performance is not inferred here.
2. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403. Archived revision January 2023; sections 3.B and 4.B, PDF pp. 7 and 11. Room-temperature assay handling and temperature-gradient guidance.
3. Revvity. AlphaLISA and AlphaScreen No-wash Assays. Tips and FAQs. Guidance to read plates near 22°C and maintain consistent temperatures.
Can a reader specified as “ambient +4°C” keep my assay at room temperature?
1. Molecular Devices. SpectraMax L specifications. Published product table lists ambient +4°C to 45°C. Specification extract; full page archive unavailable. Confirm the applicable installed-system documentation.
2. BMG LABTECH. Measurement-chamber temperature regulation. Manufacturer description of internal heat, chamber heating/cooling and ambient tracking; used for capability mechanisms, not independent performance validation.
3. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, revised January 2023, PDF pp. 7 and 11. Room-temperature protocol, signal temperature dependence and stack equilibration.
How can I tell whether the liquid in my plate has reached the reader's temperature setpoint?
1. Molecular Devices. SpectraMax L User Guide, 0112-0174 E, p. 29, Temperature Regulation. Verified web excerpt distinguishes chamber-air sensing from sample temperature and describes potentially prolonged equilibration. Full PDF download unavailable.
2. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, revised January 2023, PDF pp. 7 and 11. Room-temperature protocol, signal temperature dependence and stack equilibration.
3. PerkinElmer. AlphaScreen practical guide, PDF pp. 30 and 32 / printed pp. 24 and 26. Separate time-point wells, binding equilibration and temperature sensitivity. Historical examples are assay-specific.
Why do Alpha or glow-luminescence controls drift from the first plate to the last?
1. PerkinElmer. AlphaScreen practical guide, PDF pp. 30 and 32 / printed pp. 24 and 26. Separate time-point wells, binding equilibration and temperature sensitivity. Historical examples are assay-specific.
2. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, revised January 2023, PDF pp. 7 and 11. Room-temperature protocol, signal temperature dependence and stack equilibration.
3. Promega. ADP-Glo Kinase Assay Technical Manual TM313, revised July 2023, PDF pp. 17–18. Reaction staging, plate/reagent temperature equilibration and luminescence stability.
Should I read a cell-based luminescence assay at 37°C or at room temperature?
1. Promega. CellTiter-Glo 2.0 Assay Technical Manual TM403, revised January 2023, PDF pp. 7 and 11. Room-temperature protocol, signal temperature dependence and stack equilibration.
2. Promega. RealTime-Glo MT Cell Viability Assay Technical Manual TM431, revised December 2021, PDF pp. 3, 6–7 and 14. Nonlytic mechanism, reagent preparation, live-cell example and temperature options.
3. Promega. Nano-Glo HiBiT Lytic Detection System Technical Manual TM516, revised June 2023, PDF p. 7. Constant sample/reagent temperature, room-temperature equilibration and detection incubation.
AlphaPlex: your first measurement can change the second
1. Revvity. AlphaPlex assay development user guide. See pp. 12–14 for acquisition and optics, and pp. 14–20 for crosstalk and multiplex validation. The comparison discussed is specific to the configurations in the guide.
2. Hamamatsu Photonics. Photon-counting signal-to-noise simulator and technical explanation. Photon counting statistics and the effect of background. Numerical examples in this article are independent constructed calculations.
3. Revvity. AlphaLISA and AlphaScreen no-wash assays. Temperature guidance, signal-generation mechanisms and assay-dependent thermal sensitivity.
Choosing Alpha HTRF and alternative screening assays
A1 Revvity AlphaLISA and AlphaScreen assay principles and temperature guidance
A2 Revvity HTRF Technical Booklet
A3 Revvity HTRF PPI assay development guide
A4 Revvity HTRF signal treatment and analysis
A5 Hwang et al 2020 A homogeneous bioluminescent immunoassay to probe cellular signaling
A6 Promega Lumit TNF alpha Human Immunoassay TM689
A7 Revvity AlphaScreen TruHits interference controls
A8 Promega NanoBRET Protein Protein Interaction System TM439
A9 Auld et al Microplate Selection and Recommended Practices chapter 2020
M1 MSD electrochemiluminescence technology
A10 Yasgar et al 2012 1536 well FP assays for protein binding
A11 Primary study LIMS Kinase direct product measurement by mass spectrometry
A12 Revvity explanation of the Alpha assay hook effect
The sample got brighter when we diluted it
1. PerkinElmer. AlphaScreen practical guide. Hook effect: PDF p. 21 / printed p. 15. Temperature and assay interference: PDF pp. 30–32.
2. Revvity. AlphaLISA human IL6 kit AL223 manual. Manual-AL223-VRB1. Matrix and timing guidance: pp. 5–7; post-hook standard exclusion, dilution correction and concentration reporting: p. 8. Assay-specific instructions; the constructed curve in this essay is not IL6 performance data.
The inactive ingredient in the reagent bottle
1. PerkinElmer. AlphaScreen practical guide. PDF pp. 27–29, 32 and 34; printed pp. 21–23, 26 and 28. Historical formulation, order-of-addition, medium and temperature examples remain assay-specific.
2. Cell Signaling Technology. A2B5 Mouse Monoclonal Antibody 8763 datasheet. Formulation example only; not an endorsement for use in an Alpha assay. The calculated 0.02% stock above is hypothetical.
3. Revvity. Using the AlphaScreen TruHits kit, revision RV 1. PDF pp. 3–5 and 12: interference mechanisms, scope, alternative addition orders and the azide example. Proposed buffer-exchange and matched-spike experiments have not been performed here.
Lumit: no wash steps doesn't mean no interference
1. Hwang B. et al. A homogeneous bioluminescent immunoassay to probe cellular signaling pathway regulation. Communications Biology 3, 8 (2020). doi:10.1038/s42003-019-0723-9.
2. Promega. Lumit Glucagon Immunoassay, TM682. Revised November 2025. Sections 7 and 8A: hook effect, timing, temperature and optical considerations.
3. Promega. Lumit Immunoassay Labeling Kit, TM602. Sections 5C and 5D: antibody optimization, matrix effects and calibration.
4. Promega. Lumit HMGB1 Human/Mouse Immunoassay, TM681. Revised May 2025. Sections 5, 8B and 8C: sample matrix, temperature and spectral interference.
Why does my sample get brighter when I dilute it?
1. Anton Simeonov and Mindy I. Davis. Interference with Fluorescence and Absorbance. Assay Guidance Manual, updated 1 July 2018. Reviewed in the supplied June 2026 compilation, PDF pp. 1259–1264, particularly p. 1262.
2. Revvity. AlphaLISA human IL6 kit AL223 manual, Manual-AL223-VRB1, pp. 5–8. Matrix, incubation temperature, hook-effect and sample-dilution guidance. Assay-specific requirements.
3. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition, April 2017, printed pp. 149–153 (PDF pp. 162–166). Counting noise, background and count-rate nonlinearity. Numerical examples here are constructed.
Why does rereading an Alpha assay change its signal?
1. PerkinElmer. AlphaScreen practical guide, PDF pp. 8, 30–32 / printed pp. 2, 24–26. Signal chemistry, separate wells for time points, light exposure and temperature effects. Historical numerical examples are assay-specific.
2. Revvity. AlphaPlex assay development guide, archived edition, p. 13 and pp. 27–28. Oxidation-related second-read loss, simultaneous versus sequential acquisition and configuration-specific optical/sensitivity results.
Can sequential AlphaPlex channel reads bias the result even if both channels look stable?
1. Revvity. AlphaPlex assay development guide, p. 13 and pp. 27–28. Sequential-read oxidation, channel order and configuration-specific simultaneous/sequential comparisons.
2. PerkinElmer. AlphaScreen practical guide, PDF pp. 30–32 / printed pp. 24–26. Separate wells for time points, light exposure and temperature effects.
1536-well assays: the waiting time is part of the assay
1. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual. Sections on covers, mixing, centrifugation, evaporation and positional effects.
2. Beckman Coulter Life Sciences. Utilization of the MicroClime Environmental Lid to Reduce Edge Effects in a Cell-based Proliferation Assay. Manufacturer application study, including 1536-well culture and gravimetric evaporation measurements.
3. Promega. CellTiter-Glo 2.0 Assay, TM403. Revised January 2023. Room-temperature endpoint procedure and temperature considerations.
4. Promega. Nano-Glo HiBiT Lytic Detection System, TM516. Revised June 2023. Section 3B, note c: constant sample and reagent temperatures during measurement.
Low volume liquid handling for drug discovery
L1 Echo 650 Plus series
L2 Tecan D300e operating manual
L3 Tecan D300e software guide
L4 Tecan D300e supported buffers
L5 SPT liquid handling brochure
L6 dragonfly discovery specifications
L7 dragonfly cell dispensing application note
L8 Auld et al — Microplate Selection and Recommended Practices, NIH Assay Guidance Manual, chapter 2020; supplied 2026 compilation PDF pp 1573–1576
Waiting longer can move the competition curve
1. PerkinElmer. AlphaScreen practical guide. PDF p. 30, printed p. 24: equilibrium time course, separate wells and the cAMP incubation example. Historical assay-specific guidance.
2. Hoare SRJ (2021). Analyzing Kinetic Binding Data. Assay Guidance Manual. Supplied 2021 compilation, PDF pp. 61–79: association, dissociation, competition kinetics and limits of rate estimation. Consult the chapter's models before inferring residence time from endpoint data.
3. Invitrogen. Predictor hERG Fluorescence Polarization Assay manual. PDF p. 11, section 7.1 and Table 7: E-4031 time course. These historical results describe this assay, not a general FP incubation requirement.
4. Hamamatsu Photonics. Photomultiplier Tubes: Basics and Applications, fourth edition. Printed pp. 149–150: count-rate linearity and correction. A signal plateau alone does not establish linear detector response.
Dispensed does not mean mixed
1. Auld DS et al. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual, chapter created June 1, 2020; supplied compilation updated June 10, 2026. PDF pp. 1573–1576 / printed pp. 1551–1554: mixing, dispensing and centrifugation. The diffusion calculations here are explicitly constructed timescales.
2. Song OR et al. (2010). Confocal-Based Method for Quantification of Diffusion Kinetics in Microwell Plates and Its Application for Identifying a Rapid Mixing Method for High-Content/Throughput Screening. Journal of Biomolecular Screening 15:138–147. Printed pp. 141 and 144–146: DMSO distribution and comparison of mixing methods. Findings are specific to the tested 384-well conditions.
3. Promega. CellTiter-Glo 2.0 Assay technical manual TM403. Revised January 2023. Protocol and temperature guidance, PDF pp. 7 and 11 / printed pp. 6 and 10. Follow the instructions for the actual kit and plate format.
Let the reaction and the detector use different concentrations
1. PerkinElmer. AlphaScreen practical guide. Separate enzyme and detection concentrations: PDF p. 27 / printed p. 21. Temperature sensitivity: PDF p. 32 / printed p. 26.
2. Revvity. Alpha kinase anti-phospho antibody assays. Protocol-in-brief and Tips. Capacity estimates apply to the stated bead concentration and do not replace substrate-specific optimization.
3. Revvity. HTRF KinEASE-TK manual. Revision 07, October 2025. Reaction/detection stages and temperature: pp. 1, 3–4; substrate-dependent detection optimization: pp. 5–6. This kit's instructions are distinct from the hypothetical Alpha dilution calculation.
How do I know whether a 384- or 1536-well assay is actually mixed?
1. Microplate Selection and Recommended Practices in High-throughput Screening and Quantitative Biology. Assay Guidance Manual, Mixing and Dispensing sections. Supplied NIH compilation, PDF pp. 1573–1575 / printed pp. 1551–1553.
2. Promega. Nano-Glo Dual-Luciferase Reporter Assay, TM426, revised February 2024, sections 3.A–3.H and 4.C. Temperature, mixing, injection, reagent carryover and coincidence-reporter design.
When do I need inject-and-read measurements instead of dispensing the whole plate first?
1. Promega. Dual-Luciferase Reporter Assay System, TM040, revised August 2023, sections 4.A–4.B and 6.D. Timing, injectors and Stop & Glo reagent carryover.
2. Promega. Dual-Glo Luciferase Assay System, TM058, revised January 2023, p. 5. Ten-minute stabilization, two-hour reading window and automated-injector foaming warning.
3. Promega. Nano-Glo Dual-Luciferase Reporter Assay, TM426, revised February 2024, sections 3.A–3.H and 4.C. Temperature, mixing, injection, reagent carryover and coincidence-reporter design.
How do I test for injector carryover in a plate reader?
1. Promega. Dual-Luciferase Reporter Assay System, TM040, revised August 2023, sections 4.A–4.B and 6.D. Timing, injectors and Stop & Glo reagent carryover.
2. Promega. Nano-Glo Dual-Luciferase Reporter Assay, TM426, revised February 2024, sections 3.A–3.H and 4.C. Temperature, mixing, injection, reagent carryover and coincidence-reporter design.
3. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021, pp. 42–43, 92–99 and 159. Pathlength correction, injector operation and application-dependent cleaning.
Choosing MSD Luminex and alternative biomarker assays
M1 MSD electrochemiluminescence technology
M2 MSD U-PLEX platform highlights
M3 MSD S-PLEX ultrasensitive biomarker development study 2020
M4 Luminex xMAP Cookbook fifth edition
M5 Diasorin MAGPIX system
M6 Bio-Techne Simple Plex assay formats
M7 Quanterix Simoa technology
M8 Olink NPX frequently asked questions
M9 MSD U-PLEX high dilution panel 1 human
M11 Gunther et al 2020 Bead fluorescence versus planar ECL in human plasma
M12 McKinski et al 2025 Comparison of highly sensitive multiplex immunoassays
A12 Revvity explanation of the Alpha assay hook effect
Label free binding instruments for drug discovery
B1 Cytiva Biacore selection guide May 2026
B2 Octet RH16 specifications
B3 Octet RH16 datasheet
B4 Octet binding kinetics application note
B5 Octet small molecule binding kinetics
B6 WAVEsystem brochure
B7 waveRAPID hit discovery study
B8 Octet avoiding avidity
B9 Zhao et al 2013 — A comparison of binding surfaces for SPR biosensing, abstract and figure captions
Flow cytometers for drug discovery screening
F1 iQue 5 specifications
F2 CytoFLEX S specifications
F3 CytoFLEX plate loader C16574
F4 Attune NxT specification sheet
F5 CytKick and CytKick MAX user guide
F6 Thermo flow cytometry capabilities guide
F7 iQue cells and secreted proteins
F8 Nguyen et al 2013 — Quantifying spillover spreading for comparing instrument performance and aiding in multicolor panel design
When blocking luciferase creates more light
1. Auld et al. A specific mechanism for nonspecific activation in reporter-gene assays. ACS Chemical Biology, 2008. Experimental stabilization and reporter activation; the turnover numbers in this essay are constructed.
2. Auld et al. Mechanism of PTC124 activity in cell-based luciferase assays of nonsense codon suppression. PNAS, 2009, 106:3585–3590. Firefly and Renilla comparisons apply to the tested systems.
3. Auld et al. Molecular basis for the high-affinity binding and stabilization of firefly luciferase by PTC124. PNAS, 2010, 107:4878–4883. Adduct formation and coenzyme-A-dependent relief of inhibition.
4. Auld and Inglese. Interferences with Luciferase Reporter Enzymes. Assay Guidance Manual; supplied 2021 compilation, PDF pp. 1098–1101. Reporter lifetime, construct dependence and orthogonal assays.
5. Promega. Nano-Glo Luciferase Assay System technical manual TM369. Revised January 2022, sections 4.B and 5.C. Endpoint conditions and instrument linearity.
6. Promega. Bright-Glo Luciferase Assay System technical manual TM052. Revised March 2024, printed p. 16. Temperature dependence and heat within the reading chamber.
The inhibitor that made the reporter brighter
1. Auld and Inglese. Interferences with Luciferase Reporter Enzymes. Assay Guidance Manual; supplied 2021 compilation, PDF pp. 1098–1101. Distinguishes interference counterscreens from orthogonal confirmation. The decision panel and experiments here are proposed.
2. Promega. Nano-Glo Luciferase Assay System technical manual TM369. Revised January 2022, sections 4.B and 5.C. Room-temperature equilibration, linearity and measurement limitations.
3. Promega. Nano-Glo Dual-Luciferase Reporter Assay technical manual page. Sequential reagent additions and reporter measurements.
4. Thorne et al. Firefly luciferase in chemical biology. Chemistry & Biology, 2012, 19:1060–1072. Reporter inhibition, stabilization and assay-dependent responses.
5. Auld et al. Mechanism of PTC124 activity in cell-based luciferase assays of nonsense codon suppression. PNAS, 2009, 106:3585–3590. Firefly and Renilla comparisons in the tested systems.
6. Promega. Bright-Glo Luciferase Assay System technical manual TM052. Revised March 2024, printed p. 16. Temperature and chamber-heat effects on intensity and stability.
How can I tell whether a fluorescent screening hit is active or just interfering with detection?
1. Simeonov A, Davis MI. Interference with Fluorescence and Absorbance. Assay Guidance Manual, updated 1 July 2018. Fluorescence interferences and assay-design strategies; supplied NIH compilation, PDF pp. 1259–1271.
2. Hall MD and colleagues. Fluorescence polarization assays in high-throughput screening and drug discovery: a review. Methods and Applications in Fluorescence 2016;4:022001, section 5. Supplied full PDF; compound interference and raw-intensity checks.
How can I tell whether a luminescence hit changes the biology or inhibits the reporter reaction?
1. Auld DS and colleagues. A Specific Mechanism for Non-Specific Activation in Reporter-Gene Assays. ACS Chemical Biology 2008;3:463–470. doi:10.1021/cb8000793. Luciferase-inhibitor enrichment and reporter stabilization; archived full article.
2. Promega. Nano-Glo Dual-Luciferase Reporter Assay, TM426, revised February 2024, sections 3.A–3.H and 4.C. Temperature, mixing, injection, reagent carryover and coincidence-reporter design.
3. Promega. CellTiter-Glo 2.0 Assay, TM403, January 2023 revision, pp. 6 and 10. Room-temperature equilibration, signal stabilization and temperature gradients.
When should I use orbital averaging?
1. BMG LABTECH. Well-scanning. Orbital, spiral and matrix acquisition.
2. BMG LABTECH. How to reduce data variability in heterogenous cell samples, Figures 4–6. GFP HeLa example and spatial heterogeneity. No universal orbit diameter or improvement is inferred.
Should I increase the number of flashes or the integration time in a fluorescence assay?
1. Tecan. Infinite 200 PRO Instructions for Use, revision 1.4, June 2021, p. 77. Prompt fluorescence, flash count, delayed integration and settling.
2. BMG LABTECH. How does the number of flashes influence measurement results?. Flash averaging, concentration-dependent variability and acquisition time. Example-specific flash counts are not generalized.
3. Revvity. HTRF Technical Booklet, pp. 9–13 and 20. Long-lived donors, delayed detection, red donor/acceptor channels and excitation-source guidance.